STRENGTH
The company specializes in various high-precision electric furnaces and kilns
Brief Introduction
The high-temperature elevating atmosphere furnace introduces internationally advanced technology, environmentally friendly electric furnace, developed through independent R&D by integrating advanced technologies. It features a sophisticated, rational structure and a refined, aesthetically pleasing design. The outer casing is constructed from high-quality cold-rolled steel plate, processed by CNC machine tools, and finished with a premium, durable two-tone imported epoxy powder electrostatic spray coating, offering excellent resistance to high temperatures and corrosion. High-quality resistance wires, silicon carbide rods, or molybdenum disilicide rods serve as heating elements. The double-layer furnace shell with an air insulation layer maintains a low surface temperature. Key advantages include a balanced temperature field, low exterior surface temperature, fully adjustable heating rates, and high energy efficiency. The furnace chamber is constructed from ceramic fiber materials using CNC processes, providing exceptional thermal shock resistance, tolerance to rapid heating and cooling cycles, high corrosion resistance, and resistance to sagging, crystallization, and dusting, ensuring a long service life with no pollution. The control system employs microcomputer-based AI regulation technology, featuring PID adjustment, fully automatic control, and self-tuning capabilities. It supports multi-segment programmable profiles for various heating and holding steps, achieving high temperature control accuracy. The system utilizes integrated thyristor modules and phase-shift triggering. The protection system includes independent safeguards against over-temperature, over-voltage, over-current, leakage, and short circuits. The furnace boasts a high degree of automation, with all performance indicators meeting advanced standards.
This furnace is equipped with a vacuum pump (Model: 1 set -8 type), and a condenser tube assembly is required between the vacuum pump and the furnace interface. Operating Atmosphere: Supports atmosphere protection (compatible with various inert protective atmospheres) and includes a pre-configured vacuum connection interface.
Application
This equipment is widely used in universities, research institutes, and industrial and mining enterprises. It is an ideal device for experiments and production involving powders, electronics, metallurgy, pharmaceuticals, ceramics, sulfur, glass (new materials), chemicals, metal sintering, and metal heat treatment.
Qualification & Honor
ISO 9001:2015 Quality Management System Certification
CE Certification (EU Conformity)
Luoyang City "Model Enterprise for Civilized and Honest Operation"
"Leading Brand in China's Electric Furnace Industry"
"AAA Enterprise for Quality, Service, and Creditworthiness"
Products can withstand testing by authoritative inspection institutions; third-party verification certificates can be provided upon request.
Main Functions & Features
Energy-saving and Eco-friendly: The furnace chamber is constructed from high-purity composite alumina/ceramic polycrystalline fiber. It is lightweight with low heat storage capacity, ensuring high energy efficiency—the unit typically operates at half power on average.
Convenient Maintenance & Time-saving: Equipped with high-quality heating elements (resistance wire/silicon carbide rods/silicon molybdenum rods) that offer a long service life and easy replacement.
Integrated Design: Features an integrated structure for flexible operation, minimizing connection failures and saving valuable workspace.
High Temperature Control Precision: Utilizes premium instruments with a temperature control accuracy of ±1°C. Instruments can be supplied with third-party inspection certificates upon request.
Excellent Furnace Temperature Uniformity: Rational internal layout ensures a balanced temperature field with no dead zones within the chamber.
Microcomputer Programmable Control: Features adjustable heating rates and fully automated operation, eliminating the need for constant manual supervision.
Comprehensive Safety Protection: Automatic alarms and protection systems for over-temperature, over-pressure, over-current, leakage, thermocouple failure, and heating element breakage.
Electric lead screw lifting at furnace bottom, stable vibration-free movement, easy material loading and unloading
Wide Range of Applications: Widely used in universities, research institutes, industrial and mining enterprises for powder processing, military applications, electronics, metallurgy, pharmaceuticals, ceramics, glass, machinery, new material development, special materials, refractories, building materials, chemicals, metal sintering, and heat treatment for both experimental and production purposes.
Double-layer Shell & Air Convection Insulation: Designed with double-layer housing and an air-cooled convection layer to keep the exterior cool.
Spray-coated Exterior: Features a beautifully finished spray-coated shell with a two-tone color scheme for a professional appearance.
Proven Reputation: Established brand with a large and diverse customer base.
High Cost-performance & After-sales Service: Excellent value for money backed by comprehensive after-sales support, including a 1-year warranty and lifetime on-site repair/maintenance services.
New Design: A new generation of vacuum atmosphere furnaces featuring specialized sealing designs.
Gas Detection (Optional): Configurable with oxygen analyzers to monitor exhaust gas content (multiple gas detectors available as options)
Item |
Specification |
|---|---|
Rated Voltage |
380V |
Design Temperature |
800℃, 1000℃, 1200℃, 1400℃, 1600℃, 1700℃, 1800℃ |
Heating Rate |
≤0.1–40℃/min (Adjustable) |
Heating Element |
High-quality imported resistance wire / High-quality U-type silicon carbide rod / High-quality U-type molybdenum disilicide rod |
Temperature Control Accuracy |
±1℃ |
Temperature Control Mode |
LCD touch screen automatic control, PID regulation, intelligent microcomputer control, multi-segment programmable temperature control curve, unattended operation (automatic heating, insulation, power off when door opens) |
Temperature Measuring Element |
K (0~1300℃) / S (0~1600℃) / B (0~1820℃) |
Furnace Chamber Material |
Ceramic polycrystalline fiber / Alumina fiber / Composite alumina fiber / High-purity composite alumina fiber / Imported fiber |
Door Structure |
The door serves as a charging platform, hydraulic lifting at the bottom, smooth lifting without vibration, easy loading and unloading |
Cooling Method |
Double-layer shell, air insulation layer |
Surface Temperature Rise |
≤30℃ |
Accessories as per model |
2 heating rods, 2 rod holders, 1 crucible tongs, 1 pair of refractory gloves, 1 furnace bottom plate, 1 instruction manual & certificate |
Non-standard Customization
Custom furnace chamber sizes are available according to customer requirements.
Standard Accessories
Name |
Picture |
Quantity |
Description |
|
High-temperature Gloves |
|
1 pair |
Excellent comfort, keeps hands warm; Cut-resistant, abrasion-resistant, and heat-resistant (withstands contact with 350°C heat for 60 seconds, 100°C heat for 180 seconds). Durable. |
|
|
Heating Elements |
Silicon Carbide Rods |
|
2 pieces |
Silicon carbide elements, characterized by their high operating temperature, hardness, and brittleness, are ready for use after formation. For instance, silicon carbide rods and tubes, made from silicon carbide, can achieve a heating temperature of up to 1500°C under dry air conditions. Under vacuum conditions, the operating temperature ranges from 1000°C to 1200°C, while in a nitrogen atmosphere, the long-term use temperature reaches 1350°C. |
Silicon Molybdenum Rods |
|
2 pieces |
Silicon molybdenum rods, when heated to high temperatures in an oxidizing atmosphere, form a dense layer of quartz glass on the surface, protecting them from further oxidation. Therefore, silicon molybdenum rods exhibit high-temperature oxidation resistance. In an oxidizing atmosphere, they can reach temperatures up to 1800°C, making them suitable as heating elements for high-temperature furnaces in industries such as electronics, ceramics, magnetic materials, glass, metallurgy, and refractories. |
|
Crucible Tongs |
|
1 piece |
1.A common chemical instrument typically used for handling crucibles. Generally made of stainless steel or other non-flammable, oxidation-resistant hard materials. 2.Clean crucible tongs must be used. 3.When using crucible tongs to pick up a hot crucible, the tips should be preheated first to prevent the crucible from cracking due to localized cooling. After use, the tongs should be placed on a table or asbestos mat with the tips facing upward. 4.After the experiment, crucible tongs should be cleaned, dried, and stored in the laboratory equipment cabinet. 5.Use the curved section for gripping crucibles; the tips are for other purposes. 6.Crucible tongs are not necessarily used exclusively with crucibles; they can also be used independently. |
|
Optional Accessories List
Integrated Furnace Temp. Control |
Touchscreen Instrument |
Remote Auxiliary Module |
Observation Window |
Exhaust Hole & Chimney |
Hot Air Fan |
Crucible, Casserole, Material Rack |
Multi - material Table |
Furnace Bottom Plate |
Air Blowing |
Thermocouple |
Centralized Control Industrial Computer |
Caster Wheel |
Multi - point Temperature Measurement |
Exhaust Gas Purification Device |
Hydraulic Lifting (Manual/Auto) |
Material Table Tilting |
Vacuum & Atmosphere |
Special Note
Item |
Content |
|---|---|
|
Factory Environment |
1. Indoor use; 2. Ambient temperature range: ±5~45℃; 3. Relative humidity of surrounding environment does not exceed 85%; 4. No conductive dust, explosive gases, or gases that can severely damage metals and insulating materials around the furnace. |
|
Safety Protection |
1. When using the electric furnace for the first time or after long-term shutdown, baking is required; otherwise, it is easy to cause furnace cracking. 2. Keep clean regularly and check whether the furnace wiring is in good contact. 3. When using the electric furnace, the furnace temperature shall not exceed the rated temperature to avoid damaging the heating elements. It is forbidden to pour various flammable liquids and molten metals into the furnace. 4. During operation, generally below 300℃, the heating rate should not be too fast, because the furnace chamber is cold at the beginning of heating and needs to absorb a lot of heat. |
|
Friendly Tips |
1. To ensure the normal service life of the equipment, please do not run at the rated temperature for a long time. 2. Carefully check and verify the quantity of goods and accessories upon receipt to avoid inconvenience caused by missing or incorrect items. 3. To extend the service life of the instrument, we recommend a heating rate and cooling rate of 10℃/min. 4. The cooling rate should not exceed 5℃/min. 5. This furnace has no vacuum sealing structure, so flammable and explosive gases must not be introduced. 6. After this furnace has been used for a period of time, slight cracks may appear in the furnace chamber, which is a normal phenomenon and will not affect usage. At the same time, it can be repaired with alumina coating. |
Common Faults & Trouble Shooting
Fault Phenomena |
Fault Causes |
Troubleshooting Methods |
No power indication when turning on the control power switch |
Control circuit issue, blown fuse, or no power supply |
Check for short circuits, rectify, and replace the fuse |
Voltage present but no current during equipment operation |
Heating element broken |
Replace the heating element |
Instrument PV display shows the maximum temperature for the corresponding thermocouple type |
Thermocouple short circuit |
Replace the thermocouple |
All power supplies normal but furnace does not heat up |
Main control circuit damaged |
Notify a qualified technician for repair |
The company specializes in various high-precision electric furnaces and kilns
Every product undergoes multiple quality inspections before leaving the factory to ensure stable operation of each one
The product range is diverse and comprehensive, meeting the diverse needs of users
Provide quality assurance services as required, offer free repairs for quality issues, and provide free technical support